{"product_id":"eastron-sdm72ct-modbus-three-phase-ct-energy-meter-1a-5a-input","title":"Eastron SDM72CT-MODBUS Three-Phase CT Energy Meter – 1A\/5A Input","description":"\u003cp style=\"font-size: 16px; line-height: 1.5;\"\u003eThe \u003cstrong\u003eEastron SDM72CT-MODBUS\u003c\/strong\u003e is a \u003cstrong\u003ethree-phase multifunction energy meter\u003c\/strong\u003e for commercial buildings, distribution panels and industrial energy-management projects. It brings electrical and energy measurements together in a compact DIN-rail device.\u003c\/p\u003e\n\u003ch2 style=\"font-size: clamp(22px, 2vw, 24px); line-height: 1.3;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eThree-Phase Measurement\u003c\/strong\u003e – Monitors a 3×230\/400V AC, four-wire supply.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eExternal CT Connection\u003c\/strong\u003e – Compatible with 1A\/5A secondary inputs and a configurable CT ratio.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eElectrical Parameters\u003c\/strong\u003e – V, A, W, var, VA, PF and Hz.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eBidirectional Energy\u003c\/strong\u003e – Separate imported and exported active and reactive energy.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eRS485 Modbus RTU\u003c\/strong\u003e – Integration with compatible BMS and data acquisition systems.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003ePulse Outputs\u003c\/strong\u003e – Energy signals for compatible external counters.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eProtected Configuration\u003c\/strong\u003e – Password access to metering and communication settings.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eBacklit Display\u003c\/strong\u003e – Read electrical and energy values at the panel.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eDIN-Rail Installation\u003c\/strong\u003e – Four-module enclosure for electrical distribution boards.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003eThe manufacturer model \u003cstrong\u003eSDM72CT-M\u003c\/strong\u003e uses \u003cstrong\u003eexternal current transformers with 1A or 5A secondary output\u003c\/strong\u003e. By selecting CTs for the installation and configuring the ratio correctly, it can monitor circuits whose primary current exceeds the range of direct-connected meters.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003eIt measures \u003cstrong\u003evoltage, current, active, reactive and apparent power, power factor and frequency\u003c\/strong\u003e, together with active and reactive energy. Separate import and export readings support sites where energy can flow in both directions.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003eBuilt-in \u003cstrong\u003eRS485 Modbus RTU\u003c\/strong\u003e connects the meter to compatible controllers, data loggers and BMS platforms. Central collection makes it possible to compare electrical loads, review usage trends and build energy dashboards.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003eThe \u003cstrong\u003etwo pulse outputs\u003c\/strong\u003e offer an additional connection to compatible energy counters. The backlit LCD gives local access to measurements, while password-protected configuration helps maintain the selected communication and metering settings.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003eThe compact enclosure fits on a \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e in a suitable electrical panel. It is useful for monitoring building supply points, production equipment, HVAC loads and renewable-energy installations.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003eFor wireless LoRaWAN integration, a compatible external RS485-to-LoRaWAN converter and the required gateway, server and platform are supplied separately. The meter provides the electrical measurements through its wired Modbus interface.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003ePackage Includes\u003c\/strong\u003e — 1 × Eastron SDM72CT-MODBUS Energy Meter\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eInstallation requirements:\u003c\/strong\u003e External CTs are required and supplied separately. Select the correct primary current, secondary output and rated burden, and configure the CT ratio to match.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eRemote monitoring:\u003c\/strong\u003e Compatible external communication equipment and a monitoring platform are required for remote data access. The meter communicates through RS485 Modbus RTU.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: clamp(22px, 2vw, 24px); line-height: 1.3;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eCommercial Buildings\u003c\/strong\u003e – Record consumption at three-phase supply and distribution points.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eIndustrial Loads\u003c\/strong\u003e – Track energy use in production equipment and machinery.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eElectrical Panels\u003c\/strong\u003e – Add a central metering point to the distribution board.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eHVAC \u0026amp; Refrigeration\u003c\/strong\u003e – Compare the consumption of major building loads.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eRenewable Energy\u003c\/strong\u003e – Review imported and exported energy at suitable metering points.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eEnergy Management\u003c\/strong\u003e – Supply electrical data to dashboards and efficiency projects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: clamp(22px, 2vw, 24px); line-height: 1.3;\"\u003eProduct Downloads\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\u003ca href=\"https:\/\/www.eastrongroup.com\/eastrongroup\/2025\/07\/15\/eastronsdm72ct-mmvm-2tdinrailmounted;threephase;ctdatasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" title=\"Datasheet\" style=\"color: #0000ee; text-decoration: underline;\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.5;\"\u003e\u003ca href=\"https:\/\/www.eastrongroup.com\/eastrongroup\/2025\/07\/15\/sdm72ct-m_multi-functionmeterusermanual-1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" title=\"User Manual\" style=\"color: #0000ee; text-decoration: underline;\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Eastron","offers":[{"title":"Default Title","offer_id":54018890498384,"sku":"SDM72CT-MODBUS","price":91.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/0489\/4032\/files\/SDM72CT-M1-buJ4.webp?v=1794988233","url":"https:\/\/invibitshop.com\/products\/eastron-sdm72ct-modbus-three-phase-ct-energy-meter-1a-5a-input","provider":"InviBIT Shop","version":"1.0","type":"link"}