Industrial hydrogen sulfide (H2S) sensor for gas concentration and environmental monitoring in livestock facilities, wastewater treatment and industrial installations. This listing is the Waterproof Aviation Connector version.
Key Features
- Solid-polymer electrochemical H2S measurement.
- Simultaneous air temperature and humidity readings.
- Wired Modbus integration with compatible PLCs and data loggers.
- 2 m cable with waterproof aviation connector.
- Model / SKU — S-H2S-01 / 101990863
- Gas range — 0–100 ppm H2S; 0.1 ppm resolution
- Gas accuracy — ±5% F.S.; minimum detection limit 1 ppm
- Temperature — −40 to +85°C; ±0.2°C; resolution 0.1°C
- Humidity — 10–95% RH; ±2% RH; resolution 0.1% RH
- Power — 3.3–5.5 VDC; 5 V recommended; <5 mA, 25 mW at 5 V
- Communication — RS485 Modbus RTU; 9600 baud, 8N1
- Cable / connector — 2 m / Waterproof Aviation Connector
- Protection — IP65; protect from prolonged direct sun and rain
- Operating environment — −40 to +55°C; 15–95% RH, non-condensing
- Timing — Typical warm-up 5 min; update interval 1 s; T90 <30 s
- Integration and maintenance — Requires an external DC supply and compatible RS485 Modbus master. For LoRaWAN or cellular connectivity, use a separate compatible data logger and verify wiring and power requirements. Gas calibration and periodic maintenance are required; follow the manufacturer instructions, including calibration after approximately six months of use. F.S. means full scale.
Applications
- Monitoring hydrogen sulfide gas in wastewater treatment and industrial facilities.
Product Downloads
Specifications
| Specification | Value / Details |
|---|---|
| Model / SKU | S-H2S-01 / 101990863 |
| Gas range | 0–100 ppm H2S; 0.1 ppm resolution |
| Gas accuracy | ±5% F.S.; minimum detection limit 1 ppm |
| Temperature | −40 to +85°C; ±0.2°C; resolution 0.1°C |
| Humidity | 10–95% RH; ±2% RH; resolution 0.1% RH |
| Power | 3.3–5.5 VDC; 5 V recommended; <5 mA, 25 mW at 5 V |
| Communication | RS485 Modbus RTU; 9600 baud, 8N1 |
| Cable / connector | 2 m / Waterproof Aviation Connector |
| Protection | IP65; protect from prolonged direct sun and rain |
| Operating environment | −40 to +55°C; 15–95% RH, non-condensing |
| Timing | Typical warm-up 5 min; update interval 1 s; T90 <30 s |
Shipping Policy
We provide worldwide shipping using only tracked shipping services. Currently all our international shipments are performed by TNT Express and FedEx. Local shipments to Greece are performed either directly from us or using local shipping couriers (i.e. ELTA Courier).
We ship products within 1-3 days after the order is placed. You will be notified by email when your order is dispatched and you will receive the relevant shipment tracking number which you can use to track your shipment.
Shipment Tracking
You can use the following links to track your order using the provided tracking number in the case of international orders.
Orders shipped with TNT Express: TNT Tracking
Orders shipped with FedEx: FedEX Tracking
General Return Policy
We have a 30-day return policy, which means you have 30 days after receiving your item to request a return.
To be eligible for a return, your item must be in the same condition that you received it, unworn or unused, with tags, and in its original packaging. You’ll also need the receipt or proof of purchase.
To start a return, you can contact us at info@invibit.com. If your return is accepted, we’ll send you a return shipping label, as well as instructions on how and where to send your package. Items sent back to us without first requesting a return will not be accepted.
For any further information, help and support regarding the shipping and/or return process you can contact us at:
Email: info@invibit.com
Telephone: +30 210 421 2380