See where your facility uses electricity
How much energy goes into refrigeration, air conditioning and lighting? Which circuit causes demand peaks, and which equipment keeps running when the building is empty? InviBIT designs complete electricity metering and remote monitoring solutions, from one distribution board to facilities across multiple locations.
We combine wireless LoRaWAN EU868 meters, wired RS485 / Modbus RTU meters and a suitable monitoring application. This brings consumption by supply, circuit or end use into one view, providing a practical basis for reviewing energy performance and measuring the effect of changes.
Wireless, wired or a combination of both
Wireless LoRaWAN
Compatible meters send readings to a LoRaWAN gateway and onward to the application. This suits distributed panels and locations where installing new communication cables is difficult. Gateway placement and radio coverage are assessed for the actual site.
Wired Modbus
RS485 / Modbus RTU meters connect to an appropriate data collector or automation system. The design can use existing communication cabling and integrate with a BMS or SCADA system after compatibility has been checked.
A mixed installation
Wireless and wired measurement points can appear in the same application. A suitable RS485-to-LoRaWAN bridge can also transmit selected readings from compatible Modbus meters, with register mapping and polling intervals configured for the project.

Wireless data transmission reduces communication cabling. Electrical connections and installation of meters and current transformers still require a qualified electrician.
Measurements that support day-to-day decisions
Consumption by end use
Record energy in kWh and compare days, periods, spaces or circuits. Separately metering refrigeration, HVAC, lighting and other loads helps identify where further investigation is needed.
Power and electrical parameters
Monitor active power, voltage, current and power factor where the selected meter supports them. Identify peaks and compare the load profile before and after operational changes.
Alerts and selective control
The application can be configured for thresholds, unusual consumption or missing data. Where required, compatible smart sockets or controllers add remote ON/OFF for selected, suitable loads.
One dashboard for the complete picture
View readings from a computer or mobile device: total consumption, load profiles, period comparisons and individual measurement points. Data history, reports, user access and notification channels are defined in the project proposal.

Update intervals depend on the devices, network and monitoring requirements. An end-use breakdown requires separately measured circuits; a single main meter does not automatically identify the consumption of individual appliances.
Selected equipment from our range
These products illustrate options for different installations. Models, quantities and accessories are specified after reviewing the supplies and measurement points.

Eastron SDM230 LoRaWAN MID
Single-phase, 100 A direct-connected metering with wireless EU868 communication. For individual supplies and distribution boards.

Eastron SDM630MCT-LR
Three-phase LoRaWAN energy metering with compatible external 1 A / 5 A current transformers. For larger feeders and plant equipment.

Eastron SDM120-M Modbus
Compact, single-phase 45 A energy meter with RS485 / Modbus RTU. For wired submetering in electrical panels.

Eastron SDM630-Modbus MID
Three-phase, direct-connected energy meter up to 100 A per phase. Wired communication with a compatible Modbus collector.

Milesight CTH01
LoRaWAN power monitor with 12 current inputs and 3 voltage inputs. Supports up to 12 single-phase or 4 three-phase circuits with compatible RJ11 sensors.

Milesight WS523
LoRaWAN smart socket for appliance energy monitoring and remote ON/OFF. Select the EU version and check the load type and switching requirements.
Dragino: wireless current monitoring
For monitoring the operation of machinery, refrigeration units and other loads, the CS01 range sends current readings wirelessly to the monitoring system. The converter and current transformers are selected together to suit the installation.

Dragino CS01-LB
Four-channel LoRaWAN EU868 current-sensor converter for monitoring loads and equipment operation. Connects to compatible external current transformers selected for the required measurement range.

Dragino CS01-LB2
Four-channel LoRaWAN EU868 current-sensor converter with a 19,000 mAh battery. An alternative for monitoring current across several circuits; compatible current transformers are selected separately.

Dragino SCT013G-D-100
Split-core current transformer rated 100 A / 50 mA, for compatible Dragino CS01 inputs. Its 16 mm aperture is suitable for conductors within that diameter.

Dragino SCT024-300
Split-core current transformer rated 300 A / 50 mA with a 24 mm aperture, for compatible Dragino CS01 inputs. Selected according to the circuit current and conductor dimensions.
CS01-LB and CS01-LB2 measure current. For actual energy metering in kWh, select a suitable energy meter. The transformers shown have 50 mA outputs and must not be substituted with 1 A or 5 A models.
For current and equipment-operation monitoring, options include Milesight CT101, CT305 and Dragino CS01-LB. Current-only sensors do not provide the same energy measurement as meters that also measure voltage. Any kWh calculation based on configured voltage and power factor is an estimate.
Current transformers are matched to the meter: primary range, aperture and 1 A / 5 A, mA or proprietary connection must be checked. For example, CTH01 uses compatible Milesight RCT-RJ11 sensors. Browse all energy and power monitoring products and current transformers.
Typical applications
Retail and supermarkets
Separate visibility of refrigeration, HVAC, lighting and distribution boards. Compare consumption while the store is open and when it is closed.
Hotels and commercial buildings
Meter floors, supplies or functional areas. Give facility teams a shared view and a basis for assessing energy improvements.
Industry and warehouses
Monitor machines, motors, pumps and auxiliary loads. Identify extended running hours and changes in consumption patterns.
Public buildings and multiple sites
Bring readings from several facilities together, with clearly identified measurement points and common reports for authorised users.
A complete solution, specified for your project
InviBIT can provide meter and accessory selection, communication design, device configuration and setup of the monitoring application. Equipment, installation, integration with existing systems, platform access and support are itemised in the quotation.
For an initial proposal, tell us the number of measurement points, single-phase or three-phase supplies, expected currents, and available Modbus, LoRaWAN or Internet connections. Please also specify whether you need metering only or control of selected loads.
Price upon request
The equipment and services are selected for the requirements of your installation.
Request a project proposal| Application | Electricity metering, submetering and remote monitoring for commercial and industrial installations. |
|---|---|
| Supply configuration | Single-phase and three-phase, according to the selected meters. |
| Wireless communication | LoRaWAN EU868; compatible gateway and network server required. |
| Wired communication | RS485 / Modbus RTU through a suitable collector or automation system. |
| Hybrid connection | Compatible Modbus meters can connect through a configured RS485-to-LoRaWAN bridge. |
| Electrical parameters | kWh, active power, voltage, current and power factor, where supported by the selected meter. |
| Current transformers | Range, secondary output and connector are matched to the meter; selected separately where required. |
| Dashboard | History, charts, comparisons, reports and alerts are configured within the agreed software scope. |
| Remote control | Optional, through compatible load-control devices; subject to load suitability. |
| Update interval | Defined according to device capabilities, network conditions and project requirements. |
| Delivery scope | Models, quantities, installation, platform services and support are specified in the quotation. |