⚡ Non-invasive and self-powered current monitoring
📊 Measures real-time RMS and cumulative current
🚨 Threshold-based over/under current alerts
🔋 Energy harvesting from the monitored circuit
📡 LoRaWAN® wireless communication – Class A
📖 Description
The Milesight CT310 is a LoRaWAN smart current transformer designed for real-time, high-accuracy current monitoring in both single-phase and three-phase electrical installations. With a maximum supported current of 1000 A, it enables non-intrusive, clamp-on measurement without interrupting the power supply.
The CT310 is self-powered, harvesting energy directly from the current it measures, and features LoRaWAN Class A support for long-range, low-power wireless communication. It provides real-time RMS values, cumulative ampere-hour measurements, and configurable alarms for over-current and under-current detection.
🔧 Features
-
⚡ Current Range: 0 – 1000 A RMS
-
📈 Sampling Frequency: 3.3 kHz
-
🧮 Accuracy: ±1% (typical)
-
🔍 Resolution: 1 mA
-
⏱️ Data Reporting: Real-time RMS (1s) & cumulative Ah (1min)
-
🔋 Power Supply: Self-powered from measured circuit or USB Type-C
-
🛠️ Mounting: Clamp-on design for easy installation
-
🌐 LoRaWAN: Class A, EU868 (and other regions)
-
📦 Enclosure: IP30 rated
-
🌡️ Operating Temp: –20°C to +70°C (sensor head up to 55°C)
📂 Product Downloads
🎥 Product Video
The CT310 measures RMS current and Ah. Supported kWh values are estimates using configured voltage and power factor; it does not directly measure voltage, active power or certified energy. A 1-second sampling interval is not a 1-second LoRaWAN reporting interval. Low-current operation requires USB power according to hardware revision and reporting interval.
- Model: Milesight CT310
- Measurement: RMS AC current, up to 1000Arms per CT; up to three phases
- Accuracy: ±1%; resolution 1mA
- Sampling: 3.3kHz; mains frequency 50–60Hz
- Power: Induced current or external 5V USB-C; no battery
- Self-powered reporting threshold: Depends on reporting interval and hardware revision; use USB power below the applicable limit
- Wireless: LoRaWAN EU868 Class A, OTAA/ABP; 16dBm at EU868
- Antenna: SMA female connector, 50Ω
- Optional temperature probe: NTC, -20°C to +100°C
- Configuration: USB-C or downlink; FUOTA support
- Transceiver operating temperature: -20°C to +70°C
- CT clamp operating temperature: -40°C to +55°C
- Protection: IP30, indoor non-condensing installation
- Metering: Direct RMS current and accumulated current; any energy estimate requires configured voltage/PF and is not certified billing metering